OpenBuildings™ Station Designer Help

Align Symbols Along Path

Used to place symbol at the nearest end of selected door (arc) and aligns automatically to doors.

Accessed from:


  • Ribbon: Building Design > Electrical > Symbols > Align Symbols > Along Path


Opens the Place Symbol Along Path dialog.
SettingDescription
Symbol > Select Opens the Symbol Manager dialog. Select symbol to place. Symbol is shown as in preview box.
Base point symbol Symbol base point can be selected from available 9 options.
Cell insertion point Select Cell insertion point as symbol base point, in place of base point selection.
Height Enter symbol height manually.
Angle Select symbol angle.
Options available:
  • 0 degrees
  • 90 degrees
  • 180 degrees
  • 270 degrees
Options
  • Min Offset Start | Min Offset End | Offset Symbols — Set offset symbol for start, end and between symbols.
  • Per Segment — Select segment to place symbols with defined options per segment.
  • Reverse — Select reverse to set start on opposite side of line.
> Preview Shows preview of symbol in the drawing with selected settings. The dialog disappears momentarily. Click in the view to return to the Place Symbol Along Path dialog.
> CAD Inserts symbol arrangement in drawing into drawing, along the selected path.


Cancel Closes the dialog.
Key-in: besSymPath